Matrix Plug-and-play starting point Clinical & GCP

Matrix: eSource and Decentralized Trial Data Stream Source-of-Truth Mapping

A plug-and-play matrix for mapping every data stream in a decentralized or hybrid clinical trial, ePRO, wearables, site EHR, central lab, to its authoritative source, static or dynamic status, and true-copy export method, built before the trial starts, with a filled specimen.

Document type: Matrix

Read and copy the template below into your own quality system. It is a generic starting point for your own internal use, provided as is, with no warranty; see the Terms and License. Adopting it does not by itself create compliance.

This is a ready-to-use matrix for mapping every data stream feeding a decentralized or hybrid clinical trial to its authoritative source, before the trial starts, not after a monitor’s first query raises the question. A modern DCT can pull data from a dozen separate systems, an ePRO app, a wearable vendor cloud, the site’s own EHR, a central lab, an eConsent platform, and each one needs an explicit decision about where its source data actually lives. Replace every <<FILL: ...>> placeholder, keep one row per data stream, and route the completed matrix through your data management plan approval. A filled specimen follows. This is general guidance to adapt, not legal or regulatory advice.

FieldEntry
Protocol / study ID<<FILL>>
Matrix owner<<FILL: role, e.g. Data Management Lead>>
Version<<FILL>>
Last verified date<<FILL>>

1. Methodology

For each data stream, answer three questions in order. First, is this the first durable, contemporaneous capture of the observation, with nothing more original behind it? If yes, it is the source; if a paper form or a prior electronic entry came first, that earlier capture is the source and this stream is a transcription. Second, can the data in this system be searched, re-queried, reprocessed, or edited after capture? If yes, classify it dynamic; if it is a fixed, non-interactive record, classify it static. Third, if this system is vendor-hosted and you do not operate its database directly, what does a faithful export actually look like, and has that export been tested. A stream that fails the third question is a data integrity gap regardless of how the first two are answered.

2. The matrix

#Data streamCapture system / vendorIs this the source? (Y/N)If No, true source isStatic or dynamicTrue-copy / export methodTested before go-live? (Y/N)Owner
1<<FILL: e.g. daily symptom score>><<FILL: ePRO vendor>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>>
2<<FILL: e.g. continuous glucose readings>><<FILL: wearable vendor>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>>
3<<FILL: e.g. vital signs at a telehealth visit>><<FILL: telehealth platform>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>>
4<<FILL: e.g. concomitant medication log>><<FILL: site EHR or paper diary re-entered to EDC>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>>
5<<FILL: e.g. central lab result>><<FILL: central lab LIMS>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>>
6<<FILL: e.g. informed consent>><<FILL: eConsent platform>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>>

3. Instructions

  1. List every system that touches trial data, not only the EDC. A data stream that transits through a customer-support portal, a courier’s tracking system, or a manual reconciliation step before reaching the database is still in scope.
  2. Answer column 4 (is this the source) from the definition, not from how official the system looks. An electronic entry re-keyed from a paper original is not the source, no matter how modern the app is.
  3. For any row marked dynamic and vendor-hosted, confirm the export method in column 7 against a real, tested export, using the SaaS data portability and exit readiness checklist, before marking column 8 “Yes.”
  4. Review and re-verify this matrix at protocol amendment, at vendor change, and at defined intervals during a long-running trial, since a vendor platform update can silently change whether a record is reprocessable.
  5. File the completed matrix with the data management plan and reference it from the monitoring plan, so SDV and centralized monitoring are scoped against the actual source for each stream rather than an assumption.

4. Acceptance criteria

  • Every data stream feeding the trial database has a row, including device and sensor streams that bypass site staff entirely.
  • Every row has an explicit, justified source determination, not a default assumption that “electronic means source.”
  • Every dynamic, vendor-hosted stream has a tested, not merely contracted, export method on file before first subject in.
  • The matrix is version-controlled and re-verified on protocol amendment or vendor change.

Filled specimen

Two rows from a hybrid Type 2 diabetes trial using a continuous glucose monitor and a telehealth visit.

#Data streamCapture system / vendorIs this the source?If No, true source isStatic or dynamicTrue-copy / export methodTested before go-live?Owner
1Continuous glucose readingsGlucoTrend CGM cloud platform (illustrative vendor name)Yes, the device reading is the first captureN/ADynamic, vendor platform allows re-calibration flags and gap annotationVendor API export of raw readings plus calibration events and audit log, validated against a 50-reading sample re-importYes, tested 14 Aug 2026, export matched source for all 50 sampled readingsM. Delacroix, Data Management
2Vital signs at telehealth visitSite nurse reads values from a home blood pressure cuff over video and enters them into the EDCNo, the subject’s cuff display at the moment of reading is the true sourceThe cuff reading itself, observed but not independently captured by any systemThe EDC entry is dynamic, but it is a transcription, not the source; standard second-person or risk-based SDV logic applies, not an eSource exemptionN/A for a true-copy question (no automated capture to export); controlled by the site visit SOP and EDC entry verificationN/AR. Oyelaran, Clinical Operations

Row 2 is the instructive one: a telehealth visit looks fully electronic end to end, but the actual physical reading happens on a device nobody is capturing from directly, so it is still a transcription with all the verification obligations that implies, not an eSource stream.

Common inspection findings this matrix prevents

  • A data management plan that labels a stream “eSource” because it is electronic, when a human is actually re-keying a value observed on a separate device or form.
  • A wearable or sensor vendor’s export format discovered, mid-trial or at database lock, to be an unreadable summary rather than a faithful copy of the dynamic data.
  • No documented decision for who owns source-data status for a device stream that no site staff member ever directly observes.
  • A protocol amendment that adds a new vendor platform with no update to the source-of-truth mapping, so monitoring and SDV continue against an assumption that no longer matches reality.

How to adapt this matrix

  1. Build the row list from the protocol’s data flow diagram and every vendor contract touching trial data, not from the EDC data dictionary alone.
  2. Involve the vendor technical contact when answering the export-method column; a sales contact’s assurance is not the same as a tested export.
  3. Cross-reference each dynamic row against the static vs dynamic record classification form if the same system also serves a non-clinical GxP purpose.
  4. Confirm every reference against the current published version before issue.
Use madhadi.com as an app Full screen, works offline, one tap from your home screen.