Form Plug-and-play starting point Quality Assurance

Form: Single-Use System Supplier Extractables Data Package Review

A plug-and-play form for deciding whether a supplier's BioPhorum or BPSA-protocol extractables data package is adequate to qualify a single-use component, before it is relied on in a process-specific risk assessment, with a field table, acceptance criteria, and a filled specimen.

Document type: Form

Read and copy the template below into your own quality system. It is a generic starting point for your own internal use, provided as is, with no warranty; see the Terms and License. Adopting it does not by itself create compliance.

This is a ready-to-use form for reviewing a supplier’s extractables data package for a single-use system component (a bag, tubing set, connector, filter, or sensor) before relying on it for component qualification. It answers a narrower question than the process-specific risk assessment: is the supplier’s own study adequate on its own terms, before you ask whether it clears your process. Replace every <<FILL: ...>> placeholder and attach it to the component’s supplier file. A worked filled specimen follows the template. Verify each cited standard against the current source before you rely on it.

Field table

FieldFormatRequiredWho completesWhen
Component ID and descriptionTextYesSupplier qualityAt receipt of supplier data package
Supplier and manufacturing siteTextYesSupplier qualityAt receipt
Data package reference / report numberTextYesSupplier qualityAt receipt
Protocol basis (BioPhorum/BPOG standardized protocol, BPSA guidance, or supplier proprietary method)TextYesSupplier quality / E&L chemistryAt review
Extraction conditions used (solvents, temperature, time, surface-area-to-volume basis)TextYesE&L chemistryAt review
Analytical techniques usedTextYesE&L chemistryAt review
Lot(s) and resin/material batch(es) coveredTextYesSupplier qualityAt review
Worst-case justification (contact time, temperature, surface area relative to your intended use)TextYesE&L chemistryAt review
Adequacy decisionAccept / Accept with conditions / RejectYesE&L chemistry, QAAt review completion
Basis for decisionTextYesE&L chemistry, QAAt review completion

Instructions

  1. Confirm the component ID, supplier, and the data package reference before starting the technical review.
  2. Identify which standardized protocol, if any, the supplier used. A package generated to the BioPhorum (formerly BPOG) standardized extractables protocol or BPSA guidance carries more weight than a supplier-proprietary method with undisclosed conditions, because the standardized protocols define common extraction conditions and reporting that many users can rely on without a bespoke study.
  3. Check that the extraction conditions and analytical panel are consistent with what a controlled extraction study for this material class should include: solvents bracketing polarity, an exaggerated but justified temperature and time, and an orthogonal analytical panel (GC-MS, LC-MS, ICP-MS as applicable). A package that ran only one technique is a gap, not automatically a rejection, but the gap has to be named.
  4. Confirm the lot(s) and resin batch(es) the study covers are representative of what you will actually receive, and that the supplier has a change-notification commitment if the resin source, additive package, or manufacturing site changes.
  5. Assess worst-case fit: does the supplier’s study condition (contact time, temperature, surface area to volume) bound or exceed your intended process use. If your process is more severe than the supplier’s study conditions, the package alone is not adequate and a confirmatory process leachables study is required regardless of the decision below.
  6. Record the adequacy decision and route for QA countersignature. An “Accept with conditions” decision must name the condition (for example, a confirmatory process leachables study, or a request for updated data at the next resin lot change).

Acceptance criteria

  • The protocol basis, extraction conditions, and analytical techniques are stated, not just referenced by a report number.
  • The worst-case fit assessment explicitly compares the supplier’s study conditions to your actual process conditions.
  • An “Accept” decision is supported by a stated basis; an “Accept with conditions” decision names the condition and its owner.
  • The decision feeds the process-specific extractables and leachables risk assessment; it does not substitute for it.

Retention

Retain with the component’s supplier qualification file and reference it from the process-specific risk assessment. Retain for the life of the supplier relationship plus the record retention period defined in <<FILL: retention policy reference>>.

References

BioPhorum (formerly BPOG) standardized extractables protocol for single-use systems. BPSA (Bio-Process Systems Alliance) guidance on extractables and leachables for single-use systems. USP <1663>, Assessment of Extractables Associated with Pharmaceutical Packaging and Delivery Systems. See Extractables and Leachables and Supplier and Vendor Qualification.


Filled specimen

FieldEntry
Component ID and descriptionSingle-use bioreactor bag, 200 L, film assembly SU-BAG-200
Supplier and site<<FILL: supplier name>>, manufacturing site <<FILL: site>>
Data package referenceSupplier extractables report EXT-SUP-2026-008
Protocol basisBioPhorum standardized extractables protocol, aqueous and 50% ethanol extraction conditions
Extraction conditions40 degrees C, 24-hour and 7-day timepoints, surface-area-to-volume ratio matched to the 200 L bag geometry
Analytical techniquesGC-MS headspace and direct injection, LC-MS/HRMS, ICP-MS
Lots coveredThree resin lots across two manufacturing campaigns, 2025-2026
Worst-case justificationSupplier study conditions (40 degrees C, 7 days) exceed the process’s actual contact profile (ambient temperature, 48-hour maximum hold), so the supplier data bounds the intended use
Adequacy decisionAccept with conditions
Basis for decisionPackage is adequate on its own terms and bounds this process’s contact profile; condition: process-specific risk assessment RA-SUS-014 still required to confirm no downstream purification gap for the one flagged extractable near the process AET

Interpretation: the supplier package itself was judged technically adequate (standardized protocol, orthogonal analytics, representative lots, conservative worst-case conditions), but adequacy of the supplier study does not by itself clear the component; the process-specific risk assessment is still the gating step before the component is released for use.

Common inspection findings this form prevents

  • Relying on a supplier’s letter of guarantee with no documented review of the actual extraction conditions or analytical panel behind it.
  • No record of whether the supplier’s study conditions actually bound the site’s real process conditions.
  • A supplier resin or site change that occurs with no mechanism to learn about it, because the acceptance decision was never tied to a defined lot and change-notification commitment.

How to adapt this form

  1. Set the component and supplier package details.
  2. Work through the protocol-basis, extraction-conditions, and worst-case-fit questions against the actual supplier report, not a summary letter.
  3. Record the adequacy decision with its basis, and name any condition explicitly.
  4. Route to QA for countersignature and file with the supplier qualification record.
  5. Reference this form from the process-specific extractables and leachables risk assessment for the same component.